ENVSonic controls biofilm, algae and settlement in heat exchangers, cooling towers, process pipework and intakes with ultrasound applied from the outside of the equipment. Nothing is dosed into the water, nothing is discharged, and the plant does not shut down to fit it.
Where fouling bites
Heat exchangers, condensers, cooling towers and intakes run warm, nutrient-rich water around the clock, which is exactly what bacteria, algae and shell need. A bacterial film forms first. In an exchanger it insulates the tubes, so approach temperatures drift; in a tower it coats the basin and the fill. On seawater duty larvae then settle on the film and narrow the pipework, the tubes and the strainers.
The conventional answers are chemical dosing, with its handling, storage and discharge limits, or mechanical cleaning on a schedule the process has to be planned around.
How ENVSonic protects it
Transducers bond to the dry outside of the equipment and send short bursts of ultrasound through the wall. At the wetted surface the pressure variations stop biofilm establishing and larvae settling. Peer-reviewed work on power ultrasound shows significant reductions in algae at pilot scale and over two years in open water, and independent work on heat exchangers reports longer periods of low fouling with non-chemical treatment. The research →
- Heat exchangers and condensers: transducers on the shell and end covers, with the aim of heat transfer held near design and a longer run between openings.
- Cooling towers and chillers: transducers on the outside of the basin wall, to cut the chemical load and the cleaning.
- Process and intake pipework: transducers along the outside of the pipe, each on a footprint shaped to the pipe’s outside diameter.
- Aquaculture pens and intakes: screens and netting kept open without chemicals in the water.
Ultrasound works alongside the site’s water-treatment and risk-management plan and does not replace statutory controls. At survey we say what a system will protect, what it will not, and how the result will be measured.
Installation
Nothing is drilled, welded or opened, so there is no shutdown to fit. Systems run on 100 to 240 VAC in wall-mounted cabinets of 6 to 54 channels, with every channel tested and calibrated daily; ENVS2 adds remote monitoring through the dashboard and SCADA. Plant surveys start from the P&ID and the exchanger drawings.
What changes in service
The aim is heat transfer held near design, a lower chemical load, fewer openings and cleans, and results you can read on your own instruments. A sensible start is one exchanger or one tower, measured against a twin or its own record. Seawater-cooled process plant → · Cooling towers and HVAC → · Discuss a plant survey →
Does ultrasonic antifouling work on heat exchangers?
Yes. Transducers bond to the outside of the shell, the end covers or the connecting pipework, and the ultrasound travels through the metal to the wetted surface, where it stops biofilm forming and larvae settling. On vessels the same protection keeps box coolers and plate exchangers at design capacity across a docking interval.
Can ultrasonic treatment replace chemical dosing?
It is designed to reduce the chemical load by stopping biofilm and algae establishing on the equipment it is fitted to. How far dosing can be cut depends on the system and the site’s treatment plan, so the reduction is agreed and measured with you rather than promised in advance.
Does the plant have to shut down to install it?
No. Transducers bond to the dry side of the tank, vessel or pipe wall through the proprietary footprint, so there is no penetration and no shutdown to fit. Surveys start from the P&ID and the exchanger drawings.
How is an industrial system monitored?
Every channel is tested and calibrated daily by the control module, and a transducer that loses its bond is detected and shut down. ENVS2 adds remote monitoring and control through the ENVSonic dashboard and SCADA.
Does it work for aquaculture intakes and pens?
Yes. The same ultrasonic treatment keeps intake screens and pen netting open without chemicals in the water, which matters where the water is a food-production environment.