ENVSonic systems carry a three-year warranty on the complete system, or five years on a Monitoring & Maintenance plan. It covers the control module, transducers, proprietary footprints and cabling supplied by GLOBAtech Australia, supported by the OEM engineering team and regional partners. This page summarises the terms; the full terms and conditions are issued with the proposal and on commissioning.
What is covered
- Hardware: defects in materials and workmanship in the control module, transducers, footprints and supplied cabling for three years from the commissioning date, or five years on a Monitoring & Maintenance plan.
- The complete system: the warranty applies to the certified system as supplied, not to the control module alone.
- Support: remote diagnosis through the dashboard where fitted, replacement of a defective component, and commissioning guidance for the replacement.
Activation
Register the installation with the system serial number and the commissioning date when the system is commissioned. Registration is done by the installer or operator through the dashboard or by contacting the engineering team; the vessel record then carries the warranty status.
Five years with Monitoring & Maintenance
Join a Monitoring & Maintenance plan within six months of commissioning and the complete-system warranty extends to five years from the commissioning date, for as long as the plan stays active.
- Monitored: the system stays connected to the ENVSonic dashboard, so the engineering team sees every channel’s daily self-test.
- Ahead of failure: a weakening bond, a drifting channel or a supply problem is flagged and acted on before it costs protection.
- Maintained: a scheduled health review and firmware updates, with service visits planned around the vessel’s or plant’s programme.
Plan inclusions and terms are set out in each proposal.
Making a claim
- Contact the engineering team or your regional partner with the vessel name, the system serial number and a description of the fault; per-channel data from the dashboard speeds the diagnosis.
- We confirm the fault remotely where possible and advise whether a component should be returned or replaced in place.
- Replacement parts are shipped with fitting instructions; a regional installer attends where the operator requests it, on the terms in the proposal.
What is not covered
Damage from installation not in accordance with the transducer plan and the written guide, transducers removed or relocated without the engineering team’s approval, mechanical damage, incorrect supply voltage, and fouling on surfaces outside the protected scope agreed at commissioning. The full exclusions and limitations are in the terms and conditions issued with the proposal.
Beyond the warranty
Transducers are hermetically potted and bonded for the life of the structure. Firmware, monitoring and vessel records continue in the dashboard after the warranty period, and support is available through the OEM and regional partners. Install and support →