An ENVSonic system pays back through fuel, cleaning, docking and compliance. Which of those dominates depends on the vessel or plant, and the engineering team models it from your operating profile. Every configuration is quoted from your GA within two working days.
What a system comprises
- System size. Each transducer is one channel. ENVS1 control modules are configured with 4 or 6 channels, in panel-mount or DIN-mount versions, and cabinets combine them to provide from 6 to 54 channels depending on the application: a workboat cooling system at one end, a large hull or multi-structure install at the other. ENVS2 cabinets add remote monitoring and control for fleet-scale deployments.
- What is supplied. Control module, transducers, proprietary footprints, cabling, OEM commissioning support and a three-year warranty.
- What the yard does. Bonding and cable runs to our transducer plan and cable schedule, and class-approved penetrations where cabling enters ballast tanks.
- Retrofit or newbuild. Same hardware either way. Most retrofits need no docking.
Typical configurations
| Typical configuration | Fits | Channels | Control hardware |
|---|---|---|---|
| Workboat seawater systems | Box coolers, strainers, sea chest on a tug or pilot boat | 4 | ENVS1 4-channel module, panel or DIN mount, 12/24 VDC |
| Yacht or tug, systems plus running gear | Seawater systems and props, shafts, rudders | 4 or 6 | ENVS1 4- or 6-channel module, 12/24 VDC or dual AC/DC |
| OSV or ferry, multi-structure | Sea chests, coolers, pipework, thrusters | 6 to 12 | ENVS1 6-channel modules, one or two in a cabinet |
| Large hull, multi-structure | Hull plating plus seawater systems | 12 to 24 | 2 to 4 × ENVS1 6-channel modules in a cabinet |
| SOV, MPV or stationary asset | Full seawater system, running gear, hull | 18 to 54 | 3 to 9 × ENVS1 6-channel modules in cabinets (two 18-channel cabinets supplied to Cochin Shipyard); 54 channels is the ENVS1 maximum per system |
| Fleet or industrial, remotely monitored | Any of the above with dashboard and SCADA | Scalable | ENVS2 cabinet, 100–240 VAC |
Where the return comes from
Five things drive the return, and which one dominates depends on the vessel or plant. The calculator above models the first two as separate streams: hull and propulsion as a fuel range, and raw-water systems as the maintenance and downtime figures you enter.
- Reduced maintenance and unscheduled downtime. Fouled box coolers, sea chests and strainers raise jacket-water temperatures, force derating and end in blocked strainers, overheating alarms and unplanned repairs. Operators count the cooler and strainer cleans no longer needed, the diver or ROV interventions avoided, the off-hire days that never happen, and the anodes, dosing chemicals and biosecurity inspections that go with them. On tugs, OSVs and ferries working warm harbours this stream is often larger than the fuel saving.
- Fuel. A meaningfully fouled hull adds between 10% and 30% to fuel burn at constant speed, depending on hull form, voyage profile and severity (GLOBAtech founder letter, May 2026, citing the ISO 19030 literature). On trading tonnage this is the largest term; on a box-cooler-only install it is secondary.
- Cleaning and diver cycles on the hull. Reactive hull cleaning damages paint and accelerates the next growth cycle; stopping settlement removes the cycle and the service disruption around it. Ferry and workboat operators cite this first.
- Docking intervals and consumables. No anodes to replace, no dosing, no polishing cycle on running gear, and for most installs no docking to fit or maintain the system. Docking intervals extend when the hull stays at as-painted condition.
- Compliance. CII grading, EU ETS exposure and biofouling biosecurity rules now put a price on hull condition.
Fleet agreements
The operating model we recommend: a single-vessel pilot with agreed measurements, then standard fitment across the class. An Asia-Pacific towage operator started with two tugs in 2021 and now runs ENVSonic as standard fitment across more than 25 tugs in five classes from its designated builder. Read how it was done →
Ultrasonic vs impressed current (ICAF / MGPS)
Impressed-current copper anode systems are the incumbent in sea chests and box coolers. The comparison below sticks to what holds across makers; ask any supplier for figures on the system it offers.
| ENVSonic ultrasonic | Impressed current (ICAF / MGPS) | |
|---|---|---|
| Anodes and consumables | None. No anodes, no biocide, no dosing. | Copper (and aluminium or iron) anodes consumed and replaced over the life of the system. |
| Docking required | No docking for most installs; transducers bond through the footprint to the dry side of the sea chest or cooler, inside the vessel. | Anode replacement is usually a docking or diver job. |
| Through-hull penetrations | None. Nothing in the water flow. | Anodes sit in the sea chest or strainer; wet-side installation. |
| Power draw | Driven at the full 60 W rating on every burst; typically 6 to 8 W average per transducer, because the system pulses rather than running continuously (ENVS1). | Low: a DC supply drives current to the anodes, set to the seawater flow. |
| Monitoring | Per-channel health, daily calibration, unbonded-transducer detection; remote monitoring and control on ENVS2. | Anode current shown at the control panel; anode wear checked at inspection. |
| Certification | FCC, CE and RCM for the complete system. | Varies by maker; ask for the certificates that cover the system offered. |
| Ongoing maintenance | None scheduled: no consumables, daily self-calibration, per-channel diagnostics. | Anode inspection and replacement on a fixed cycle. |
Configure a system → · Compare all antifouling methods → · Request a proposal →