Straight answers to the questions fleet operators, yards and plant engineers ask before they specify ultrasonic antifouling. Anything not covered here: ask the engineering team. How does ultrasonic antifouling work? Bonded transducers transmit curated bursts of ultrasonic energy into the structure. Pressure variations in the water form microscopic non-inertial cavitation at the surface, which ruptures…

Straight answers to the questions fleet operators, yards and plant engineers ask before they specify ultrasonic antifouling. Anything not covered here: ask the engineering team.

How does ultrasonic antifouling work?

Bonded transducers transmit curated bursts of ultrasonic energy into the structure. Pressure variations in the water form microscopic non-inertial cavitation at the surface, which ruptures algae and bacteria cell walls and makes the surface uninhabitable for settling larvae. Nothing enters the water column. The technology in depth →

Does ultrasonic antifouling actually work?

Where the physics works cleanly, yes, and the service record shows it: sea chests, box coolers, strainers and seawater pipework, and the hulls and running gear of working vessels such as tugs, ferries and workboats. One towage operator went from a two-tug pilot to standard fitment on more than 25 tugs. On the full hull of a large deep-sea ship it is not yet proven, and we say so. The evidence →

Why do results from ultrasonic systems vary so much?

Because the result depends on how much energy reaches the wetted surface and on every transducer still working a year later. Three questions sort one system from another: ask for the energy delivered into the structure rather than the watts on the label, ask how each channel is verified and how often, and ask how the mount is qualified. How ENVSonic answers them →

Does it replace antifouling paint or a marine growth prevention system (MGPS)?

On the hull it works with the coating, not instead of it: it stops growth settling, so the paint is not worn away by cleaning. In sea chests, box coolers and strainers it is the marine growth prevention system: IMO’s 2023 Biofouling Guidelines list ultrasound alongside anodes, electrolysis and ultraviolet as MGPS types. It does the job of impressed-current (ICAF) anodes or dosing with no consumables, no biocide and no metal ions in the seawater. MGPS and the IMO guidelines → · The methods compared →

Does it work on heat exchangers and industrial cooling water?

Yes. Transducers bond to the outside of the exchanger shell, the pipework or the basin, and the plant does not shut down to fit them. We survey from the P&ID first and say what a system will protect and what it will not. Seawater-cooled process plant → · Cooling towers and HVAC →

Which vessels is it used on?

Harbour tugs, offshore support vessels and workboats; pilot boats and port craft; ferries; processing barges; superyachts; and the sea chests, coolers and niche areas of deep-sea ships. Tugs and offshore → · Pilot boats → · Deep-sea fleets → · Superyachts →

Does it need dry docking or through-hull fittings?

No. Transducers bond to the inside of the structure via the proprietary footprint, so most installations need no drilling, welding or docking. The exception is cabling into ballast tanks, which needs class-approved penetrations and is usually done at a docking.

What does it protect?

Sea chests, box coolers, strainers, heat exchangers and raw-water pipework; hull plating and submerged structures; propellers, shafts, rudders, stabilisers and thrusters; cooling towers, intakes and aquaculture infrastructure. Applications →

Can it be retrofitted to a vessel already in service?

Yes. Retrofit is routine and can be commissioned without an extended lay-up; two Australian Ro-Pax ferries were fitted in service with an active fouling problem. Read the case →

How much power does it draw?

Low. Each channel is driven only as hard as its calibration requires, with Economy, Standard and Boost modes. Per-transducer and per-system figures are published on each product page.

Is it audible, and does it affect sonar or marine life?

The system is inaudible to crew and operates outside the bands used by navigation sonar. Underwater radiated noise depends on drive power; ENVSonic publishes measured levels and runs each transducer at the lowest effective dose. Ask for the measurement note.

What certification does it carry?

FCC, CE and RCM for the complete system, control module, cabling and transducers together. Certificates are available on request and on the product pages.

How do I know it is working?

The control module monitors every transducer, calibrates daily, detects an unbonded transducer and isolates the channel. ENVS2 adds remote monitoring and control through the dashboard and SCADA, with lifetime data recording.

What is the warranty and who supports it?

Three years on the complete system, or five years when the system joins a Monitoring & Maintenance plan within six months of commissioning. Supported by the OEM engineering team in Australia and regional partners. Install and support →

What are niche areas?

IMO’s term for submerged areas that foul faster than the main hull because of their shape, their flow or poor coating cover: sea chests and gratings, box coolers, sea inlet pipes, thrusters, propellers, shafts, stern tube seals and rope guards, rudder hinges and stabiliser apertures. They are a small share of the wetted area and a large share of the biofouling. On large deep-sea ships, the sea chests, coolers and pipework are where ENVSonic is fitted today. Niche areas explained →

How do we list ENVSonic in our biofouling management plan?

As the MGPS for each niche area it protects: type ultrasound, manufacturer GLOBAtech Australia, the model (ENVS1 or ENVS2), the areas from the transducer plan, the service life and the operating manual, which Australia asks to be kept with the Biofouling Record Book. Log its checks and maintenance in the record book. What the plan should say →

Does ENVSonic help with Australia’s and New Zealand’s biofouling rules?

It is part of the proactive management both look for. Since June 2022 Australia has asked commercial vessels for a biofouling management plan and record book that list each MGPS, or for cleaning within 30 days before arrival; New Zealand requires a clean hull on arrival and lists marine growth prevention systems as best practice. ENVSonic keeps the niche areas it protects clean between dockings; the coating, the plan and the record book stay with the operator. The rules by region →

How do I get a quote?

Send the GA and a note on where the vessel or plant operates. The engineering team returns a transducer plan and proposal, typically within two working days. Request a proposal →

Talk to the engineers who built it

As the OEM we design the transducers, footprint, electronics and firmware, build them in Australia, and support every system end to end, backed by a three-year complete-system warranty, or five years with a Monitoring & Maintenance plan.