ENVSonic

Marine growth prevention systems (MGPS) for niche areas

Marine growth prevention systems keep biofouling out of a ship’s niche areas: sea chests, box coolers, strainers, thrusters and running gear. What they are, what IMO’s 2023 Biofouling Guidelines and the national rules ask for, what an inspection checks and how to choose one.

A marine growth prevention system (MGPS) is the anti-fouling system for the parts of a ship that coatings cannot protect well: the sea chests, box coolers, strainers, sea inlet pipes, thrusters and running gear that IMO calls niche areas. Anodes, electrolysis, ultraviolet light and ultrasound all do the job, and IMO’s 2023 Biofouling Guidelines list each of them. ENVSonic is an ultrasonic MGPS.

In short

  • An MGPS protects the niche areas: sea chests, box coolers, strainers, pipework, thrusters and running gear, where biofouling builds first.
  • IMO’s 2023 Biofouling Guidelines name anode, ultrasound, electrode, electrolysis and ultraviolet systems. ENVSonic is ultrasound.
  • Each MGPS is described in the ship’s biofouling management plan, and its maintenance and any downtime go in the Biofouling Record Book.
  • The guidelines recommend an inspection at least every 12 to 18 months, niche areas first, with the MGPS rated at each one. Australia, New Zealand, California and Brazil have their own rules as well.

By the GLOBAtech Australia engineering team, who have designed and built ENVSonic since 2006. Checked against IMO resolution MEPC.378(80) and Australia’s biofouling management requirements (version 4). Reviewed November 2026.

What a marine growth prevention system is

IMO defines an MGPS as “an AFS used for the prevention of biofouling accumulation in niche areas or other surface areas”, where an anti-fouling system (AFS) can be a coating, a surface treatment or a device. The guidelines recommend “a combination of AFC and MGPS, suitable for different submerged areas”: the coating on the main hull, and an MGPS where coatings wear, are hard to apply or see the wrong flow.

The example biofouling management plan in the guidelines asks for the MGPS type as “anode, ultrasound, electrode, electrolysis, ultraviolet radiation or other”. They work in different ways:

  • Anodes: copper and aluminium anodes, usually driven by impressed current, release ions into the seawater drawn through the sea chest and cooling system.
  • Electrolysis: seawater is electrolysed to produce hypochlorite, which is dosed into the intake.
  • Ultraviolet: treats the water as it passes through the pipework.
  • Ultrasound: transducers on the dry side of the sea chest, cooler or pipe make the wetted surface uninhabitable for settling larvae, algae and bacteria. Nothing is dosed and nothing is consumed.

The plan records each system’s type, what it discharges (the example lists chlorine and noise), its service life and its maintenance. The methods compared →

How ultrasonic antifouling keeps a surface clean
1234
  1. The transducer bonds through its footprint to the inboard side of the plating, inside the vessel.
  2. Short bursts of ultrasound travel through the steel.
  3. At the wetted surface the ultrasound drives non-inertial cavitation: a thin, constantly disturbed layer where larvae, algae and barnacles cannot settle.
  4. Nothing is released into the water: no biocide, no anodes.

Niche areas: where biofouling builds first

The guidelines define niche areas as “a subset of the submerged surface areas on a ship that may be more susceptible to biofouling than the main hull owing to structural complexity, different or variable hydrodynamic forces, susceptibility to AFC wear or damage, or inadequate or no protection by AFS”. They are a small share of the wetted area and a large share of the biofouling: slow flow, shelter and warm water let growth settle, and they are hard to inspect or clean in the water.

The guidelines and their example plan name:

  • sea chests and their inlet gratings;
  • box coolers and the engine cooling system;
  • sea inlet pipes and overboard discharges;
  • thrusters and tunnel gratings;
  • propellers, propeller shafts, stern tube seals and rope guards;
  • rudder hinges and stabiliser apertures;
  • bilge keels, moon pools and the fire-fighting system.

For sea chests the guidelines are specific: “Internal surfaces and inlet gratings of sea chests should be protected by an AFS that is suitable for the flow conditions of the area over the gratings and through the sea chest.”

Where it goes: sea chest and box cooler
1234
  1. Sea chest: transducers on the dry side of the chest wall.
  2. Box cooler: transducers on the casing or top plate, inside the vessel.
  3. Strainer and pipework: transducers on the outside of the body and pipe wall.
  4. Nothing is fitted in the water flow and nothing passes through the hull.

What the biofouling management plan says about the MGPS

The guidelines recommend a biofouling management plan for every ship, and a Biofouling Record Book kept for the life of the ship, on paper, electronically or within the planned maintenance system. For the MGPS, the plan sets out the “process for monitoring and maintenance of MGPS as per the manufacturer’s instructions to ensure their effectiveness”, and the record book logs its repairs and maintenance.

Australia’s requirements set the minimum for the MGPS entry: manufacturer, model, type, service life, and whether the operating manual is held in the record book. They also say what the record book must log over the system’s life: any observed reduction in efficacy, downtime, malfunction or missed maintenance, with dates; any operation beyond the expected service life; and the date and place of any time the system was not operating as the plan says.

ENVSonic details for the plan

Plan entryENVSonic
TypeUltrasound (ultrasonic MGPS).
ManufacturerGLOBAtech Australia Pty Ltd.
ModelENVS1 control modules or cabinets with ENVS1 transducers, or ENVS2 for high-output installations.
Areas protectedFrom the vessel’s transducer plan, area by area (for example sea chest × 2, box cooler × 4).
DischargeNo biocide and no metal ions. The system emits ultrasound at the protected surfaces.
MonitoringEach transducer is tested and calibrated daily and shuts down if it becomes unbonded. Channel status shows at the control module and, where the system is connected, on the ENVSonic dashboard.
MaintenanceAs set out in the operating manual, with a Monitoring & Maintenance plan available.

Ask for these details, with the service life and your transducer plan →

What a biofouling inspection checks

The guidelines tie inspections to monitoring. A ship that does not monitor the performance of its anti-fouling systems should have the first inspection within 12 months of installing them; where monitoring shows they are performing adequately, it can be up to 18 months. After that, inspections should be at least every 12 to 18 months, more often as systems age, and the niche areas named in the plan are inspected first.

At each niche area the inspector records the condition of the MGPS: intact and effective in preventing biofouling, not effective, or in need of calibration or maintenance (table 5 of the guidelines). Have ready:

  • the biofouling management plan, with the MGPS entry and the plan of protected areas;
  • the Biofouling Record Book, with installation, maintenance and any downtime entries;
  • the MGPS operating manual;
  • the system’s own status record since the last inspection;
  • photos or video from the last inspection.

ENVSonic tests and calibrates every channel daily and shuts down a transducer that loses its bond, so a channel that needs attention shows on the control module, and on the dashboard where connected, rather than at the next inspection.

Choosing an MGPS: seven questions to ask

The answers go straight into the management plan, so ask them before you choose.

  1. Which surfaces does it protect, area by area? Ask for the list: sea chest walls and gratings, coolers, strainers, pipework, running gear. The guidelines ask for the inside of the sea chest and its gratings to be protected by a system suited to their flow.
  2. What will the plan record as its discharge? The example plan asks for each MGPS’s discharge (“chlorine, noise or other”). Check that it is accepted in every port on your trading pattern.
  3. What does it consume, and what is its service life? Australia’s plan asks for the service life. Ask what wears out, how often it is replaced and what that involves.
  4. Can it show when, and where, it was not working? Australia’s record book logs every period of downtime, malfunction or reduced efficacy. Ask how the system tells the crew, and what record it keeps.
  5. What does fitting take? A docking, hull penetrations, hot work in the sea chest, or none of these.
  6. What is the evidence? Certification of the complete system, and results from vessels like yours after years in service, not months.
  7. Who supports it where you trade? Commissioning, spares and service in your ports, and who reads the data.

The rules by region

IMO. The 2023 Guidelines for the control and management of ships’ biofouling (resolution MEPC.378(80), adopted on 7 July 2023) replaced the 2011 guidelines. They are guidance, and IMO has begun work on a legally binding framework.

Australia. Since 15 June 2022, commercial vessels arriving in Australian territory report their biofouling management before arrival and show one of three things: a biofouling management plan and record book, cleaning of all biofouling within 30 days before arrival, or an alternative method approved in advance. Hull and niche areas may be inspected on arrival.

New Zealand. Vessels have had to arrive with a clean hull since 2018 under the Craft Risk Management Standard. Long-stay vessels may carry only a slime layer and gooseneck barnacles, and the Ministry for Primary Industries lists marine growth prevention systems among the best-practice measures.

California. Since 2017 the State Lands Commission has required vessels arriving at California ports to carry a biofouling management plan consistent with the IMO guidelines, including the details of each MGPS and the management of niche areas.

Brazil. NORMAM-401 (2025) asks vessels over 24 m for a biofouling management plan and record book.

This is a summary for orientation, not legal advice: check the current text with the authority before planning a call.

Where ENVSonic fits

ENVSonic is an ultrasonic MGPS. Transducers bond to the dry side of the sea chest, box cooler, strainer body or pipe through the proprietary footprint, inside the vessel: no drilling, no welding and, for most installs, no docking. It is certified FCC, CE and RCM as a complete system.

Where it goes: running gear
1234
  1. Shaft: transducers on the shaft log, inside the vessel.
  2. Rudder: transducers at the rudder stock.
  3. Thrusters: transducers on the thruster tunnel, on the dry side.
  4. The ultrasound travels through the metal to the propeller, shaft and rudder. Nothing sits in the water flow.

In service: MRL Resources’ four 184 m processing barges, a 25-tug fleet on standard fitment and S/Y Encore’s seawater systems after thirteen years. Request a transducer plan →

Sources

Talk to the engineers who built it

As the OEM we design the transducers, footprint, electronics and firmware, build them in Australia, and support every system end to end, backed by a three-year complete-system warranty, or five years with a Monitoring & Maintenance plan.